DMS-30LCD Series
3? Digit, LCD Display Digital Panel Voltmeters
Performance/Functional Speci?cations
Typical at T A = +25°C and supply voltage = +5V (using the single-ended input circuit)
or +9V (using the differential input circuit   ), unless otherwise noted.
Analog Inputs
Min.
Typ.
Max.
Units
Physical/Environmental
Full Scale Input Range:
Operating Temperature
0
+60
°C
DMS-30LCD-0
DMS-30LCD-1
±200
±2
mV
Volts
Storage Temperature
Humidity (non-condensing)
–20
0
+75
95
°C
%
DMS-30LCD-2
DMS-30LCD-3
±20
±200
Volts
Volts
Case Material
Weight
Polycarbonate
0.75 ounces (21 grams)
Input Impedence:
? Applies for transient or continuous overvoltages applied to (+) INPUT HI (pin 11)
DMS-30LCD-0, -1
DMS-30LCD-2, -3
Overvoltage Protection ?
DMS-30LCD-0, -1, -2
DMS-30LCD -3
Common Mode Voltage Range ?
CMRR (dc to 60Hz)
100
0.8
1000
1
86
±100
±250
±2
Volts
Volts
Volts
dB
with (–) INPUT LO (pin 12) properly connected. Pin 12 is not overvoltage
protected (see Figure 1). Voltages applied to pin 12 should not exceed the
supply voltage.
? Listed spec applies to 5V-powered models only. For 9V-powered models, both
(–) INPUT LO (pin 12) and (+) INPUT HIGH (pin 11) must always be at least
1.5V above –BATTERY (pin 3) and at least 1.5V below +BATTERY (pin 1).
? See Technical Notes.
Ordering Information
Control Inputs ?
Decimal Pt. Placement (Pins 4-6):
DMS-30LCD - 1 - 5
-C
Functionality
Logic Compatibility
Display Test (Pin 2)
Backlight (Pin 2)
Tie to pin 3 to activate
TTL (on 5V-powered models)
Tie to pin 1 to activate
Tie to pin 3 to turn on backlight
Input Range:
0 = ±200mV
1 = ±2V
2 = ±20V
Power Source:
Add -C for RoHS
Leave blank for standard
models.
Add B for backlit models.
Performance
Sampling Rate
Accuracy (1 minute warm-up):
2.5 reading per second
3 = ±200V
Accessories:
5 = +5V
9 = +9V
DMS-30LCD-0 (Vin = +0.19V)
DMS-30LCD-1 (Vin = +1.9V)
±1
±1
±2
±2
Counts
Counts
DMS-30-CP
DMS-BZL1-C
DMS-BZL2-C
Panel cutout punch
DMS-30 bezel assembly
DMS-30 bezel assembly with sealing gasket
DMS-30LCD-2 (Vin = +19V)
±2
±3
Counts
Add-On Application Boards:
DMS-30LCD-3 (Vin = +190V)
Zero Reading (Vin = 0 Volts)
Temperature Drift (0 = +60°C)
“–001”
±2
“000”
±0.2
±3
“001”
±0.4
Counts
Cnts/°C
DMS-EB-C
DMS-EB-DC/DC-C
DMS-EB-RMS-C
DMS-EB-AC/DC-C
Multi-purpose (gain/offset, 4-20mA, etc.)
Provides isolated +5V power
For true rms measurements of ac voltages
For ac line-powered applications
+1.23V Reference Out (Pin 9)
+1.20
+1.23
+1.25
Volts
A panel-mount retaining clip is supplied with each model.
Power Supply Requirements (5V Models)
Supply Voltage
+4.75
+5.00
+5.25
Volts
Supply Current:
TECHNICAL NOTES
Standard Models
800
1200
μA
Backlit Models – 45
Power Supply Requirements (9V Models)
60
mA
1. +1.23V REFERENCE OUTPUT (Pin 9): This pin is the output of the
meter’s precision +1.23V internal reference, and it is referenced to
ANALOG COMMON (pin 10) which sits at a potential of approximately
Supply Voltage
+7.5
+9.00
+14.0
Volts
+2V. This output should be buffered if used to drive external loads
Supply Current:
since sourcing more than 15μA from pin 9 can affect both the initial
Standard Models
Backlit Models
350
45
600
60
μA
mA
accuracy and temperature drift of the meter.
2. ANALOG COMMON (Pin 10): This pin is connected to an internal,
Display
low-noise, “relative” ground. It is used in certain differential and “?oat-
Display Type and Size
Polarity Indication
Overrange Indication
3? digit, 0.4"/10.2mm high LCD
Autopolarity ("–" for negative Vin)
"–1_ _ _ " for negative inputs
"1_ _ _ " for positive inputs
ing” measurements as described in the Applications section of this
data sheet and Ap Note 3 of the DATEL Panel Meter Catalog. Pin 10
should not be connected to pin 3 (5V RETURN/–BATTERY) or to
your system’s analog ground.
www.murata-ps.com/dpm
06 Jan 2011
email: sales@murata-ps.com
MPM_DMS30LCD.D02 Page 2 of 6
相关PDF资料
DMS-30LCDA-4/20S-C METER LCD SELF-POWERED 3.5DIG
DMS-30PC-1-RH-C DPM LED MINI 2VDC SUPER-BRIGHT
DMS-30PC-4/20S-24GS-I-C DPM LED 24V SUPPLY 3.5DIG GREEN
DMS-40LCD-0/1-5-C DPM LCD 200MV/2VDC 4.5DIGIT
DMS-40LCD-4/20S-C METER LCD SELF-POWERED 4.5DIG
DMS-40PC-1-RL-BCD-C DPM LED 2VDC 4.5DIG BCD LP RED
DMS-40PC-4/20S-24RS-I-C METER DISP LED 4.5DIG 24V RED
DMU-30ACV-1-DR-C VOLT METER LED 200ACV 0.1V RED
相关代理商/技术参数
DMS-30LCD-2-5 功能描述:数字面板表 3.5 Digit Volt Meter +-20V / +5V RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS30LCD-2-5 制造商:Murata Power Solutions 功能描述:INDICATOR DMS 30LCD-2-5
DMS-30LCD-2-5B 功能描述:数字面板表 3.5 Digit Volt Meter +-20V / +5V Backlit RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-30LCD-2-5B-C 功能描述:数字面板表 3.5 Digit Volt Meter +-20V / +5V Backlit RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-30LCD-2-5-C 功能描述:数字面板表 3.5 Digit Volt Meter +-20V / +5V RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-30LCD-2-9 功能描述:数字面板表 3.5 Digit Volt Meter +-20V / +9V RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-30LCD-2-9B 功能描述:数字面板表 3.5 Digit Volt Meter +-20V / +9V Backlit RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
DMS-30LCD-2-9B-C 功能描述:数字面板表 3.5 Digit Volt Meter +-20V / +9V Backlit RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM